Hospital Cleanroom Design and Construction

Hospital Cleanroom Design and Construction

Place of Origin:
Vietnam
Brand Name:
Viet Panel
Usage:
Certificate:
ISO 9001
Main market:
FDI in Vietnam

Contact infomation

Contact name: Mr. Cai (Eng/Vie)
Mobiphone:+84 984 050 786

Product & service detail

HOSPITAL CLEANROOM DESIGN AND CONSTRUCTION
 
Hospital cleanrooms are installed to ensure a sterile environment for surgical procedures, medical instrument sterilization areas, and post-operative recovery rooms. Hospital cleanrooms are typically installed in the following areas: operating rooms, minor surgery rooms, surgical corridors, sterilization areas, recovery rooms, ICU, and CCU.
 
What makes hospital cleanrooms different?
 
Hospital cleanrooms are spaces where microbial particles are controlled at specific airborne concentration levels and minimized as much as possible. In addition, temperature, humidity, and pressure must be precisely regulated to suit medical usage purposes. Beyond investing in air purification systems, hospitals also pay close attention to cleanroom doors and medical instruments to ensure the highest level of sterility.
 
 
Under current healthcare conditions, most hospitals are facing overcrowding. Meanwhile, cross-infection among patients can easily occur if surgical, post-operative, or medical instrument sterilization areas do not meet sterility requirements. If surgical conditions are not well controlled, hospitals not only have to treat new patients but also extend treatment durations for existing ones. This directly contributes to the persistent overcrowding problem in hospitals.
 
Inadequate surgical and treatment conditions also negatively affect patient health. Issues such as prolonged recovery time and post-operative infections can result in long-term consequences in terms of both health and financial burden for patients and their families. Therefore, hospital cleanrooms are mandatory facilities and must always operate under optimal sterile conditions.
 
Standards for hospital cleanroom design
 
Depending on usage purposes, hospital cleanrooms are designed according to specific criteria. Hospital cleanrooms must strictly comply with international medical regulations such as GMP, WHO-GMP, and EU-GMP. Specifically, hospital cleanroom areas must be supplied with clean, sterile air at optimal temperature and humidity levels.
 
In addition, hospital cleanroom design in Vietnam must comply with the following standards:
 
  • TCVN 4088 - 1985: Climatic data for construction design
  • TCVN 5687 - 1992: Ventilation, air conditioning, and heating - Design standards
  • TCVN 2622 - 1995: Fire prevention and fire protection for buildings and structures - Design standards
Key parameters in hospital cleanroom design
 

 
Hospital cleanroom construction process
 
 
Step 1: Receive requirements from the hospital and conduct an on-site survey of the cleanroom installation area. VietPanel experts directly measure parameters and assess environmental conditions within the hospital to provide optimal consultation.
 
Step 2: Structural layout, area size, airflow rate, pressure levels, and other factors are evaluated to develop a complete cleanroom design. The design proposal is discussed and approved by hospital representatives before installation begins.
 
Step 3: Proceed with cleanroom construction using specialized equipment and materials, strictly adhering to construction requirements to ensure airtightness, pressure control, and compliance with airborne particle standards.
 
Step 4: Conduct inspection and acceptance testing before the hospital cleanroom is officially put into operation.
 
Step 5: Provide warranty services for the cleanroom project. After a period of use, certain criteria may no longer be fully met however, with proper warranty and maintenance, the cleanroom can continue operating under optimal sterile conditions.
 
How to choose a reputable cleanroom contractor?
 
Today, it is not difficult to find a cleanroom design and construction contractor. However, ing a reputable company that ensures high-quality design and construction requires thorough research. One of the top choices for hospitals in need of cleanroom construction is Viet Panel Cleanroom Design & Construction Company.
 
Viet Panel Co., Ltd. is one of the pioneers in hospital cleanroom design and construction, with over 10 years of experience. VietPanel experts provide clients with essential consultation on standards, design solutions, materials, and equipment to ensure optimal performance upon project completion.
 
For detailed consultation, please contact our hotline: +84 2226 535 699 / +84 984 050 786
 
Viet Panel Construction Co., Ltd. - One of the leading and most reputable companies in hospital cleanroom construction and installation.

Viet Panel Cleanroom - Viet Panel Construction Company Limited

Viet Panel Cleanroom - Viet Panel Construction Company Limited
Address:
Dong Phu Village, Phu Lam Ward, Tien Du District,Bac Ninh, Viet Nam
Telephone:
+84 222 6535699, +84 914573288, +84 984050786

Contact Infomation
What can we do for you?
Contact name: Mr. Cai (Eng/Vie)
Mobiphone: +84 984 050 786
Yellow Pages Support
Get in touch with this company? Yellow pages can help you !
Contact name: Ms Amy Phung
Mobiphone: +84 914 261 828
(Zalo/ What'sapp)
Are you an Enterprise?

Create a free Listing to introduce your business and be visible to your potential customers

_________________________________

YELLOW PAGES CONTACT
+84 24.3636.9512 (Ext 312)
Hotline/ Zalo: +84 914 261 828 (Ms Amy)

Are you an Enterprise?
Create a free Listing to introduce your business and be visible to your potential customers !
If you have any questions, please email us at contact@yellowpages.com.vn

QUICK SEARCH INDEX | YELLOW PAGES CATEGORIES
Start with A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
VIETNAM YELLOW PAGES - VIETNAM BUSINESS DIRECTORY
(Governed by Viet Business Information And Technology Joint Stock Company)
Content manager: Phung Thi Tuyet Mai
Head Office: 222B Giap Bat St., Giap Bat Ward, Hoang Mai Dist., Hanoi, Vietnam
Head Office: Floor 6, Vinafood 1 Building, 94 Luong Yen St., Bach Dang Ward, Hai Ba Trung Dist, Hanoi, Vietnam
Branch: 4th Floor, Bach Viet Building, 65 Tran Quoc Hoan Street, Ward 4, Tan Binh District, Ho Chi Minh City, Vietnam
Business license number: 0104478506, issued by Hanoi Authority For Planning & Investment
Yellow Pages Hotline: (+84) 914 261 828 (Zalo/ What'sapp/ Skype/ Line)
Tel: +84. 24 3636 9512 (ext 312) - Fax: +84. 24 3636 9371 - E-mail: contact@yellowpages.com.vn