TT
|
Specifications
|
Unit
|
Target level
|
Test standards
|
1.
|
Burning time of 01 sample when leaving the burning flame.
|
s
|
≤ 15
|
EN 14973:2006
ISO 340:2007
QCVN 01:2011/BCT
|
Total burning time of 06 samples when leaving the burning flame.
|
s
|
≤ 45
|
||
Embers maintenance time of 01 sample after the flame goes out
|
s
|
≤ 60
|
||
2.
|
Resistor
|
Ω/m
|
≤ 3x108
|
ISO 284:2003
QCVN 01 : 2011/BCT
|
Width
(mm)
|
Thickness
(mm)
|
Reliability
(N/mm)
|
EP layer structure
(Polyester-Nylon)
|
|||
2-layer
|
3-layer
|
4-layer
|
5-layer
|
|||
200 ÷ 2200
|
3÷35
|
200
|
2EP100
|
|
|
|
300
|
2EP150
|
3EP100
|
|
|
||
400
|
2EP200
|
3EP125
|
4EP100
|
|
||
500
|
|
3EP150
|
4EP125
|
5EP100
|
||
600
|
|
3EP200
|
4EP150
|
5EP125
|
||
800
|
|
3EP300
|
4EP200
|
5EP150
|
||
1000
|
|
|
4EP250
|
5EP200
|
||
1200
|
|
|
4EP300
|
|
||
1500
|
|
|
|
5EP300
|
||
1600
|
|
|
4EP400
|
|
||
2000
|
|
|
4EP500
|
5EP400
|
Should you need any further information, please do not hesitate to contact us!